← Back to Cedrix
Sample Report · 03 / 04
Splunk MCP Monitor · Cedrix v1.8.0
cedrix.io · info@cedrix.io
📝 Prompt
"List the motors at high risk of failure within the next 24 hours. Use a machine-learning model on the last 30 days of data."

Risk summary

3
Stop now
(0–12 h)
5
Maintain in
first 12 h
5
Maintain in
24–48 h
~88%
Model
confidence

🔴 Critical risk — urgent maintenance required

#MotorRisk30-day trendDE bearingNDE bearingOilAction
1GM199.8 / 10⬆ +280.5 °C (3×)373 °C🚨 Stop now
2GM029.6 / 10⬆ +40 °C (10 %)546 °C MAX385 °C81.4 °C🚨 Stop now
3GM098.9 / 10⬆ +129.9 °C (52 %)497 °C MAX328 °C82.4 °C🚨 Stop now
4GM068.2 / 10⬆ +30 °C (8 %)472 °C MAX353 °C80.7 °C⚠ First 12 h
5GM077.8 / 10⬆ +20 °C (5 %)467 °C MAX331 °C80.8 °C⚠ First 12 h
6GM017.5 / 10⬆ +18 °C (5 %)463 °C MAX330 °C80.5 °C⚠ First 12 h
7GM167.2 / 10⬆ +10 °C (2 %)528 °C MAX310 °C⚠ 24 h
8GM117.0 / 10⬆ +5 °C (1 %)525 °C MAX339 °C⚠ 24 h

Risk-score visualization

GM19
9.8
GM02
9.6
GM09
8.9
GM06
8.2
GM07
7.8
GM01
7.5
GM16
7.2
GM11
7.0
© 2026 CEDRIX · Sample Report — anonymized 1 / 2
Sample Report · 03 / 04
Failure Prediction · Page 2
cedrix.io

🟠 High risk (24–48 h)

MotorBearing MaxTrendAction
GM03528 °CStableMaintain in 24 h
GM04431 °C⚠ FaultyBring spare online
GM13513 °CStableMaintain in 24–48 h
GM31415 °CAnomalyInspect
GM10512 °CConcerningMaintain in 24–48 h

🟡 Medium risk (48–72 h)

MotorObservationAction
GM27Mechanically lockedBring spare online
GM0530 K hours, stoppedReplacement needed
GM23Cooling faultBring spare online
GM2530 K hours of ageReplacement needed
GM28High standard deviationMaintain in 48–72 h
GM12High standard deviationMaintain in 48–72 h
GM14High standard deviationMaintain in 48–72 h
GM29Low efficiencyMonitor

ML risk factors

Bearing-temperature trend (30-day) — fast rise is a failure indicator. GM19: +280 °C (most at risk, 3× jump). GM09: +130 °C (52 % increase). GM02: +40 °C (10 % increase).
Standard deviation — high variability is a vibration / failure risk. Top 5: GM10 (69 °C), GM05 (56 °C), GM09 (54 °C), GM12 (51 °C), GM14 (45 °C).
Cooling-system faults are clustering. GM02 and GM09 oil temperatures > 82 °C — suspect a plant-wide cooling or lubrication issue.

Urgent action list (24 h)

1
0–12 h: GM19, GM02, GM09 → STOP. GM04, GM27 → bring spares online. GM23 → inspect.
2
12–24 h: GM06, GM07, GM01, GM16 → fault diagnosis (high bearing temp).
3
Plant-wide: Cooling-system check — GM02, GM09, GM23 spikes are correlated.
4
Lab: Oil analysis (GM02, GM09) — particle count and viscosity check.
5
Vibration measurement: GM10, GM05, GM09 — high standard-deviation cluster.
🛡
Data sovereignty: 30 days of historical data were processed through the Cedrix gateway; site name, IP and operator identifiers were anonymized before reaching the AI model. The ML model runs locally; data is not exfiltrated.
© 2026 CEDRIX · cedrix.io · info@cedrix.io · +90 532 331 24 18 2 / 2